Unitech Group, Burntwood, Staffordshire - Roofclad
menu close icon

Unitech Group, Burntwood, Staffordshire

Client

Unitech Group

Location

Burntwood, Staffordshire

Specification of Work

Asbestos cement roof replacement, gutter refurbishment and solar PV installation

Project Length

8 months

Project Overview

Roofclad Systems refurbished the roof of Unitech Group’s 90,000 sq ft live production facility in Burntwood, Staffordshire.

The works included replacing 5,555m² of asbestos cement roofing, refurbishing the gutters, and installing an insulated roof with integrated solar PV to improve energy efficiency and weather protection.

Careful planning kept production running safely throughout the project.

Key Results

  • 5,555m² of asbestos cement roofing safely removed and replaced.
  • 0.16 W/m²K U-value achieved with the new insulated composite roof panels.
  • 25-year Platinum Plus System Guarantee for the new Tata Steel roofing system.
  • 592 solar panels installed, with an estimated annual generation of 240,967 kWh.
  • Projected 3-year ROI based on anticipated annual energy savings.
  • Improved weather protection through a fully refurbished guttering system and new roofing details.
  • Minimal disruption to ongoing production throughout the eight-month project.

Before / After

Before
After

Client Challenges

The project presented several technical and operational challenges:

  • Deteriorating roof sheets: Widespread weathering and cracking required the asbestos cement roof to be fully replaced.
  • Corroded fixings: Rusted and loose fixings contributed to the deterioration of the existing roof covering and its weatherproofing performance.
  • Failing gutters: Poor-condition gutters caused water ingress, threatening the building and operations.
  • Complex penetrations: Flues and vents required bespoke flashings to ensure a weatherproof finish.
  • Structural obstructions: Steel bars found beneath the rooflights had to be cut back before installation.
  • Maintaining production: Asbestos cement sheet removal and roof replacement required careful coordination to protect people, equipment and production areas.

Asbestos cement sheets were removed intact into specialist skips. Progressive Monarflex sheeting, safety netting, scaffold edge protection, PPE and regular toolbox talks protected the live facility throughout.

Our Solution

Roofclad Systems developed a comprehensive refurbishment solution combining asbestos cement roof replacement, gutter relining and solar PV installation.

The existing roof sheets were carefully removed under controlled conditions and replaced with a modern insulated composite roofing system. Before the new roof panels were installed, the existing gutters were relined using the Weatherfast Guttering system to restore effective rainwater management.

New internal and external ridge flashings, together with bespoke details around the flues and vents, provided a secure and weather-resistant finish. Triple-skin GRP rooflights were also incorporated to introduce natural light into the facility.

By integrating the solar PV installation into the roof refurbishment, Roofclad Systems helped the client avoid the future cost and disruption of removing and reinstalling solar panels when the ageing roof eventually needed replacing.

What we delivered

  • Asbestos removal: Safely removed and disposed of 5,555m² of asbestos cement roof sheeting in accordance with applicable asbestos regulations and controlled procedures.
  • Insulated roofing system: Installed Tata Steel Trisomet composite roof panels with 120mm insulation, achieving a U-value of 0.16 W/m²K. The system was supplied with a 25-year Platinum Plus System Guarantee.
  • Gutter refurbishment: Installed a Weatherfast Guttering system to improve rainwater management and restore the performance of the existing gutters.
  • Natural daylight: Installed Rooflights Direct Trilite Ultra 36 FAIR factory-assembled triple-skin rooflights.
  • Bespoke weatherproofing: Installed new internal and external ridge flashings, with tailored detailing around existing flues and vents.
  • Solar PV installation: Installed 592 solar panels with an estimated annual electricity generation of 240,967 kWh and a projected payback period of approximately three years return on investment (ROI), based on the client’s financial assessment.

The Result

The completed refurbishment provided Unitech Group with a modern, insulated and weatherproof roofing system, significantly improving the condition and long-term performance of the building envelope.

The new Tata Steel Trisomet roofing system achieved a U-value of 0.16 W/m²K, while upgraded gutters, rooflights and bespoke flashings improved weather protection and natural daylight.

The integrated 592-panel solar PV installation is estimated to generate 240,967 kWh of renewable electricity annually, supporting the client’s long-term energy strategy.

Through careful planning, phased working and close coordination with the client’s operational team, the eight-month programme was delivered with minimal disruption to ongoing manufacturing activities.

By combining roof replacement and solar PV installation within a single coordinated project, Roofclad Systems also helped avoid the additional costs and disruption associated with installing solar panels onto an ageing roof that would subsequently require replacement.

Client Testimonial

“Roofclad Systems worked safely and coordinated effectively with our on-site operations. The team responded well to challenges, maintained good Health & Safety standards and delivered quality workmanship. The installation team were helpful and easy to work with, making it a positive experience overall.”

– Stuart Harrison, General Manager – Unitech Group

Interested in how we can help you?

Speak to our trusted team today.

Related Projects